Product specifications and models are not all uploaded, if necessary, you can contact the online personnel. My WhatsApp +8618923754918 Look forward to hearing from you thank you.
SDBT-MSB-1L-ZU-K-2-LE
8150173
Electrical connection 1, connector system:Open end
Operational voltage range DC:10 V - 28 V
Switching element function:N/O contact
Switching output:Non-contacting, 2-wire
Electrical connection 1, connector system
Technical Data
- DesignFor T-slot
- Conforms to standardEN 60947-5-2
- Symbol00991144
- ApprovalRCM trademark
- CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
- UKCA marking (see declaration of conformity)To UK instructions for EMC To UK RoHS instructions
- KC markKC-EMV
- Special characteristicsOil resistant
- Note on materialsRoHS-compliant Free of halogen Free of copper
- Measured variablePosition
- Measuring principleMagneto-resistive
- Ambient temperature-20 °C ... 70 °C
- Repetition accuracy0.2 mm
- Switching outputNon-contacting, 2-wire
- Switching element functionN/O contact
- Switch-on time≤2.5 ms
- Switch-off time≤2.5 ms
- Max. switching frequency480 Hz
- Max. output current50 mA
- Max. switching capacity DC1.4 W
- Voltage drop≤2.8 V
- Short circuit current ratingno
- Overload protectionNot available
- Rated operational voltage DC24 V
- Operational voltage range DC10 V ... 28 V
- Reverse polarity protectionno
- Electrical connection 1, connection typeCable
- Electrical connection 1, connector systemOpen end
- Electrical connection 1, number of connections/cores2
- Connection outlet orientationIn-line
- Cable length2 m
- Cable characteristicStandard Suitable for energy chains
- Material cable sheathPUR
- Material insulating sheathPP
- Wire endsCut off bluntly
- Type of mountingScrew-clamped Insertable in the slot from above
- Max. tightening torque0.3 Nm
- Mounting positionoptional
- Product weight24 g
- Material housingPC
- Material union nutHigh-alloy stainless steel
- Switching status indicationYellow LED
- Ambient temperature with moving cable-20 °C ... 70 °C
- Degree of protectionIP67 IP68 To IEC 60529
- LABS (PWIS) conformityVDMA24364 zone III
- Suitability for the production of Li-ion batteriesMetals with more than 1% by mass of copper, zinc or nickel are excluded from use.The exceptions are nickel in steel, chemically nickel-plated surfaces, circuit boards, cables, electrical plug connectors and coils
- Cleanroom classClass 4 according to ISO 14644-1