If you have a product request, please contact me.
Pressure sensor
SPAN-B2R-G18M-PNLK-PNVBA-L1
Part number: 8035534
Start value for pressure measuring range
|
-1 bar
|
End value for pressure measuring range
|
1 bar
|
Switching element function
|
N/C or N/O contact, switchable
|
Pneumatic connection
|
Male thread G1/8 - Female thread M5
|
Analogue output
|
0 - 10 V - 4 - 20 mA - 1 - 5 V
|
The extremely compact and attractively priced pressure sensor SPAN is amazingly flexible. It can be used in a wide variety of applications thanks to switchable electrical outputs and a very wide range of options for pressure measuring ranges and pneumatic connections.
- For monitoring compressed air and non-corrosive gases
- For network monitoring, regulator monitoring, leak testing, object detection
- Relative measurement method based on a piezoresistive measuring cell
- Serial communication integrated using IO-Link® 1.1
- Compact design 30x30 mm
- High-contrast display with blue backlight
- Suitability for the production of Li-ion batteries : Metals with more than 1% by mass of copper, zinc or nickel by mass are excluded from use. Exceptions are nickel in steel, chemically nickel-plated surfaces, printed circuit boards, cables, electrical plug connectors and coils
- Symbol : 00995685
- Approval :RCM trademark c UL us listed (OL)
- CE mark (see declaration of conformity) : To EU EMC Directive In accordance with EU RoHS Directive
- CE marking (see declaration of conformity) : To UK instructions for EMC To UK RoHS instructions
- Certificate issuing authority : UL E322346
- Note on materials : RoHS-compliant
- Measured variable : Relative pressure
- Measurement method : Piezoresistive pressure sensor
- Start value for pressure measuring range : -0.1 MPa
- Start value for pressure measuring range : -1 bar
- Start value for pressure measuring range : -14.5 psi
- End value for pressure measuring range : 0.1 MPa
- End value for pressure measuring range : 1 bar
- End value for pressure measuring range : 14.5 psi
- Max. overload pressure : 5 bar
- Overload pressure : 0.5 MPa
- Overload pressure : 5 bar
- Overload pressure : 72.5 psi
- Operating medium : Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases
- Note on operating and pilot medium : Lubricated operation possible
- Media temperature : 0 °C ... 50 °C
- Ambient temperature : 0 °C ... 50 °C
- Accuracy in ± % FS : 1.5 %FS
- Repetition accuracy in ± %FS : 0.3 %FS
- Temperature coefficient in ± %FS/K : 0.05 %FS/K
- Switching output : 2 x PNP or 2 x NPN, switchable
- Switching function : Window comparator, Threshold value comparator ,Auto difference monitoring
- Switching element function : N/C or N/O contact, switchable
- Max. output current : 100 mA
- Type of mounting : Front panel mounting , Via thread ,Via wall/surface bracket